Enari Instruments And Controls
7C, Jalan Uranus AJ U5/AJ,
Seksyen U5,
40150 Shah Alam,
Selangor, Malaysia.
+6011-1878 1899

Kyoritsu KEW5020 Power Logger

Previous 5 / 6 Next

Kyoritsu KEW5020 Power Logger Kyoritsu  Power Quality Analyzers


Download Files

5010_20-1E.pdf (1.21 MB)
CE
3 channel inputs for the simultaneous recording of Leakage Current , Load Current and Voltage
• Power Quality analysis
• Large capacity for storing 60,000 data points
• Lowpass Filter will filter out the harmonics
• LED flickers when the preset current/voltage value is exceeded
• CALL:Confirmation of recorded data
• Selection of One-time mode or Endless mode
• Non Volatile Memory
• Battery power indicator
• The userfriendly PC software ''KEW LOG Soft 2'' is supplied
• Continuous measuring time:Approx. 10 days (Alkaline Battery)
  • TRUE RMS
  • USB
  • External

  • 3 channel inputs for the simultaneous recording of Leakage Current, Load Current and Voltage
  • Large Capacity for storing 60,000 data points
    • 60,000 data points can be recorded when 1ch is used, and when all the three channels are used, 20,000 data points per channel can be recorded
  • Lowpass Filter will filter out the harmonics (Cutoff Frequency = Approx. 160Hz)
  • LED flickers when the preset current / voltage value is exceeded
  • CALL: Confirmation of recorded data
    • The following can be displayed: number of recorded data points, (max+ min+ peak) value for each channel complete with time/date information in the Normal recording mode. (Detected values (i.e. when values are outside preset limits ) can be displayed in other recording modes)
    • RECALL: The last 10 recorded data points including time/date can be recalled on the logger display
  • Selection of One-time mode or Endless mode
    • One-time on: Recording will stop when memory is used up
    • One-time off: Overwrite the old data, and store the latest data
  • Non Volatile Memory
    Recorded data will be retained even if the batteries are exhausted or replaced due to the presence of a nonvolatile memory (guaranteed for 10 years)
  • Battery power indicator
    Indicates battery voltage in 4-levels
    (It is possible to use the logger for a further approx. 24 hours even after the warming symbol is flashing)
  • The userfriendly PC software ''KEW LOG Soft 2'' is supplied
    • Supplied with the user friendly software ''KEW LOG Soft 2''. This permits editing, analysis and graphical display of data.
    • The recorded data is downloadable onto a PC via USB cable.
    • Variation of the measured voltage and current data can be confirmed simultaneously on the PC display monitor. (only on KEW 5020)
    • Simplified Power Integration
      (The ''KEW LOG Soft 2'' uses current and voltage recorded to calculate the integral power consumption)
  • Continuous measuring time: Approx. 10 days (Alkaline Battery)

Normal Recording Mode
(AC 50/60Hz, Sine wave, Input: 10% or more of the range at CH1)

Range RMS Accuracy
100.0mA ±2.0%rdg±0.9%f.s.+ Accuracy of Sensor
Other ranges ±1.5%rdg±0.7%f.s.+ Accuracy of Sensor
Crest Factor 2.5 or less: RMS accuracy (sine) + 2%rdg + 1%f.s.

*Max, Min and Instant Peak values in Normal Recording mode are just reference values:
their accuracies aren't guaranteed.

Trigger Recording Mode (AC 50/60Hz sine wave)

Range Accuracy
100.0mA ±3.5%rdg±2.2%f.s.+ Accuracy of Sensor
Other ranges ±3.0%rdg±2.0%f.s.+ Accuracy of Sensor

Capture Recording Mode

Range Accuracy
100.0mA ±3.0%rdg±1.7%f.s.+ Accuracy of Sensor
Other ranges ±2.5%rdg±1.5%f.s.+ Accuracy of Sensor
Recording mode Normal, Trigger, Capture, Power Quality Analysis
Operating system Successive Approximation
(CH1 single synchronized sampling)
Rated max. working voltage AC 9.9Vrms, 14V peak value
Number of input channel 3ch
Measuring method True RMS
RMS measuring interval approx. 100ms
Sampling interval Normal/Trigger mode : approx. 1.65ms/CH
Capture mode : approx. 0.55ms (waveform: at every 1.1ms)
P.Q.A mode : approx. 0.55ms
Current range 8146 (30A type) : 100.0/1000mA/10.00/30.0A
8147 (70A type) : 100.0/1000mA/10.00/70.0A
8148 (100A type) : 100.0/1000mA/10.00/100.0A
8121 (100A type) : 10.00/100.0A
8122 (500A type) : 50.00/500.0A
8123 (1000A type) : 100.0/1000A
8128 (5A type) : 5.000A/(50.00A)
8127 (100A type) : 10.00A/100.0A
8126 (200A type) : 20.00A/200.0A
8125 (500A type) : 50.00A/500.0A
8124 (1000A type) : 100.0A/1000A
8130 (1000A type) : 100.0/1000A
Voltage range 8309 (600V type) : 600.0V
Low battery warning Battery mark display (in 4 levels)
Over-range indication ''OL'' mark is displayed when exceeding the measuring range
Auto power off Power-off function operates automatically after a switch remains for 3min. (when recording is stopped)
Possible measurement time Approx. 10 days (with alkaline LR6 batteries)
Applicable standards IEC 61010-1:2001 CAT III 300V Pollution degree2
IEC 61326 (EMC standard)
Dimensions 111(L)×60(W)×42(D)mm
Weight Approx. 265g
Included Accessories Alkaline battery LR6×4pcs, 9118 (Carrying case)
PC software ''KEW LOG Soft 2'', 7148 (USB cable)
Instruction manual, Quick manual, Install manual,
USB Notice sheet
Optional Accessories 8146/8147/8148 (Leakage & Load current Clamp Sensor),
8121/8122/8123 (Load current Clamp Sensor),
8128/8127(*1)/8126(*1)/8125(*1)/8124 (Load current Clamp Sensor),
8130(*1) (Flexible Clamp Sensor),
8320 (AC Adapter),
9135 (Carrying bag), 9119 (Hard carry case),
7185 (Extension cable for sensor)

*1 When you use the sensors with KEW5010/5020, please check the ''Applicable model list'' to check if 
  your KEW5010/5020 can be used with the sensors.

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

Switch to Mobile Version
Recent Updates
Subscribe Newsletter
1
Hello! Thanks for visiting my site. Please press Start button to Contact with Admin :)

Start